KONSERVASI ENERGI PADA GEDUNG KANTOR SEKRETARIAT DAERAH KOTA DENPASAR

Main Article Content

Gde Wikan Pradnya Dana I Gede Dyana Arjana Cok Gede Indra Partha

Abstract

Regional Secretariat Building Denpasar in 2017 experienced a separation in two parts.
The separation resulted in the empty room, even though are empty room turned out to
consumption building power in 2018 continued to experience enchancement. The study has
been done there is the room that has the intensity of energy consumption which do not compty
with SNI. Solutions that can be given is to replace the type of split standard air conditioner (AC)
into a type of low watt air conditioner (AC). Replacement type split standard air conditioner (AC)
1,5 PK became type of low watt air conditioner (AC) 1,5 PK can make saving of up 11,62 % or
Rp 21.068.468,00. Saving electric energy consumption on lighting system can be done by
installing an automatic switch with time or by using an a light sensor system.

Downloads

Download data is not yet available.

Article Details

How to Cite
WIKAN PRADNYA DANA, Gde; DYANA ARJANA, I Gede; INDRA PARTHA, Cok Gede. KONSERVASI ENERGI PADA GEDUNG KANTOR SEKRETARIAT DAERAH KOTA DENPASAR. Jurnal SPEKTRUM, [S.l.], v. 7, n. 2, p. 73-80, june 2020. ISSN 2684-9186. Available at: <https://ojs.unud.ac.id/index.php/spektrum/article/view/61437>. Date accessed: 28 mar. 2024. doi: https://doi.org/10.24843/SPEKTRUM.2020.v07.i02.p10.