Study of Transformer Lifetime Due to Loading Process on 20 KV Distribution Line

  • A.A.N. Amrita
  • W.G. Ariastina
  • I.B.G. Manuaba

Abstract

Power transformer is very important in electric power system due to its function to raise or lower the voltage according to its designation. On the power side, the power transformer serves to raise voltage to be transmitted to the transmission line. On the transmission side, the power transformer serves to distribute the voltage between the main substations or down to the distribution voltage. On the distribution side, the stresses are channeled to large customers or lowered to serve small and medium customers. As the power transformer is so importance, it is necessary to protect against disturbance, as well as routine and periodic maintenance, so that the power transformer can operate in accordance with the planned time. Some factors that affect the duration of the power transformer is the ambient temperature, transformer oil temperature, and the pattern of load. Load that exceeds the maximum efficiency of the transformer which is 80% of its capacity will cause an increase in transformer oil temperature. Transformer oil, other than as a cooling medium also serves as an insulator. Increasing the temperature of transformer oil will affect its ability as an isolator that is to isolate the parts that are held in the transformer, such as iron core and the coils. If this is prolonged and not handled properly, it will lead to failure / breakdown of insulation resulting in short circuit between parts so that the power transformer will be damaged. PLN data indicates that the power transformer is still burdened exceeding maximum efficiency especially operating in the work area of PLN South Bali Area. The results of this study, on distribution transformers with different loads, in DS 137, DS 263 and DS 363, show that DS 363 transformer with loading above 80% has the shortest residual life time compared to DS 263 and DS 137 which loading less than 80%.

Downloads

Download data is not yet available.

References

[1] Abdul Kadir, 1989. Transformator. Penerbit PT. Elex Media Komputindo – Kelompok Gramedia, Jakarta
[2] Janny Olny Wuwung, (2010). Pengaruh Pembebanan terhadap Kenaikan Suhu pada Belitan Transformator Daya Jenis Terendam Minyak. Jurnal Tekno, Volume 07, No. 52, April 2010.
[3] Sumanto, 1991. Teori Transformator. Edisi Pertama, Cetakan Pertama. Penerbit Andi Offset, Yogjakarta. ISBN : 979–533–047-0.
[4] Syafriyudin, (2011). Perhitungan Lama Waktu Pakai Trasformator Jaringan 20 kV di APJ Yogjakarta. Jurnal Teknologi, Volume 4 Nomor 1, Juni 2011, 88-95.
[5] Sofyan, Afriyastuti Herawati, (2015). Pengaruh Pembebanan terhadap Effisiensi dan Usia Transformator (Studi Kasus Transformator IV Gardu Induk Sukamerindu Bengkulu) Berdasarkan Standar IEC 60076-7. Jurnal Amplifier, Vol. 5 No.2 Nopember 2015. ISSN : 2089-2020.
[6] Winarso, (2014). Estimasi Umur Pakai dan Rugi Daya Transformator. Jurnal Techno, ISSN 1410-8607, Volume 15, No. 2, Oktober 2014. Hal. 50-55.
Published
2018-08-31
How to Cite
AMRITA, A.A.N.; ARIASTINA, W.G.; MANUABA, I.B.G.. Study of Transformer Lifetime Due to Loading Process on 20 KV Distribution Line. Journal of Electrical, Electronics and Informatics, [S.l.], v. 2, n. 2, p. 25-28, aug. 2018. ISSN 2622-0393. Available at: <https://ojs.unud.ac.id/index.php/jeei/article/view/44890>. Date accessed: 21 nov. 2024. doi: https://doi.org/10.24843/JEEI.2018.v02.i02.p01.

Most read articles by the same author(s)

1 2 > >>