EFEKTIVITAS SISTEM PENGOLAHAN INSTALASI PENGOLAHAN AIR LIMBAH SUWUNG DENPASAR TERHADAP KADAR BOD, COD, DAN AMONIA
Abstract
The effectivity of waste water treatment systems in Suwung Waste Water Treatmant Installation Denpasar,was investigated, by analyzing its effluent Biological Oxygen Demand (BOD), Chemical Oxygen Demand (COD)
and ammonia contents. The aims of the research are to determine the effectivity of each stage of waste water
treatment and the optimum detention time of waste water in aerated lagoon and sedimentation pond, in order to
reduce the BOD, COD and ammonia concentration.
The results showed that the effectivity of treatment systems of waste water in Suwung Denpasar was low.
The percentages of the reduction of BOD5, COD and ammonia in content stage I were 14.29, 15.66, and 33.74%
respectively. More over, the reduction percentages in stage II were 20.83, 14.43, and 17.39% respectively. On the
other hand, the reduction percentages from the initial to final stages were 32.14% for BOD5, 27.83% for COD and
45.26% for ammonia. The optimum detention time of waste water in aerated lagoon and sedimentation pond for
reducing parameters was 5 day and 40 hour respectivel
Downloads
Download data is not yet available.
How to Cite
SULIHINGTYAS, Wahyu Dwijani; BUDIARSA SUYASA, I W.; INDRA WAHYUNI, Ni M..
EFEKTIVITAS SISTEM PENGOLAHAN INSTALASI PENGOLAHAN AIR LIMBAH SUWUNG DENPASAR TERHADAP KADAR BOD, COD, DAN AMONIA.
Jurnal Kimia (Journal of Chemistry), [S.l.], nov. 2012.
ISSN 2599-2740.
Available at: <https://ojs.unud.ac.id/index.php/jchem/article/view/2813>. Date accessed: 21 nov. 2024.
Issue
Section
Articles
Keywords
effectivity, treatment systems, waste water, detention time
This work is licensed under a Creative Commons Attribution 4.0 International License