PENENTUAN Cu, Pb, Cd, dan Zn DALAM AIR SECARA STRIPPING POTENTIOMETRI DENGAN ELEKTRODA KONVENSIONAL DAN KOMBINASI
Abstract
This paper discusses the development of stripping potentiometric methods for reliable determination of Cu,Pb, Cd, and Zn in natural water. The electrode systems used were the conventional and combined ones. The
formation of intermetallic compound between Cu and Zn was overcame with the addition of gallium ions. The
method involved two stripping cycles during which copper was initially determined on its own, followed by
simultaneous determination of Pb, Cd and Zn after addition of 150 mg/L gallium ions. The optimum conditions for
reliable determination of the metals with the use of the conventional electrode were 0.01 M HCl, 10 mg/L Hg (II), a
deposition potential of -1200 mV and a deposition time of 30 seconds, while those with the use of the combined
electrode included 0.01 M HCl, 10 mg/L Hg (II), a deposition potential of -700 mV for Cu and -1300 mV for the
other three metals and a deposition time of 10 seconds. It was also found that the use of the combined electrode gave
lower detection limit and wider linear concentration range for the four metals.
Downloads
Download data is not yet available.
How to Cite
SAHARA, E..
PENENTUAN Cu, Pb, Cd, dan Zn DALAM AIR SECARA STRIPPING POTENTIOMETRI DENGAN ELEKTRODA KONVENSIONAL DAN KOMBINASI.
Jurnal Kimia (Journal of Chemistry), [S.l.], nov. 2012.
ISSN 2599-2740.
Available at: <https://ojs.unud.ac.id/index.php/jchem/article/view/2707>. Date accessed: 22 nov. 2024.
Issue
Section
Articles
Keywords
sripping potensiometry, electrode conventional, combined, Cu, Pb, Cd, Zn
This work is licensed under a Creative Commons Attribution 4.0 International License