Determination of Patient Dose on Head Computed Tomography Scan on Risk Factors of Cataract Using Size-Specific Dose Estimate (SSDE)

  • Shinta Palupi Universitas Udayana
  • Ni Luh Putu Trisnawati Universitas Udayana
  • Winardi Tjahyo Baskoro Universitas Udayana
  • Rozi Irhas Radiologi Rumah Sakit Umum Bali Jimbaran

Abstract

Research has been done on determining the patient's dose on a Computed Tomography (CT) Scan of the head using the Size Specific Dose Estimate (SSDE) method and the risk factors for cataracts. SSDE values ??were obtained from Computed Tomography Dose Index Volume (CTDIvol), Anterior Posterior (AP) and Lateral (LAT) values. Data were obtained from 30 patients in the group of children aged 5-14 years and 30 patients in the adult group aged 15-50 years. The mean SSDE value for the children group was 52.387 mGy and the average value for the adult group was 49.664 mGy. The mean SSDE value of children is greater than that of adult patients, this is because the diameter of the head of the children group is smaller than the diameter of the head of the adult group. One organ that is sensitive to X-ray radiation is the eye lens. If the lens of the eye gets more than 500 Gy of radiation, it will increase the risk of cataracts. The risk factor for cataract was obtained from the SSDE value and the eye lens tissue weight factor was 0.12. The risk of cataract in this study is still below the standard value set by the ICRP in 2011 which is 500 mGy. While the percentage risk of cataract occurrence for the children group was 1.257% and for the adult group was 1.192%.

Downloads

Download data is not yet available.

References

[1] Munir Misbahul, Dosis Radiasi Dan Faktor Resiko Pada Pemeriksaan Computed Tomography Scan Whole Abdomen 3 Fase, Skripsi, Program Studi Fisika Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2011.
[2] Apriantoro dkk, Dosis Radiasi Lensa Mata Pada Pemotretan Orbita Postero Anterior (PA) Axial dan PA Axial Reverse, Trijurnal Lemlit Trisakti, Jurusan Radiodiagnostik dan Radioterapi, Politeknik Kesehatan Kemenkes Jakarta II, 2019.
[3] ICRP, The 2007 Recommendations of the International Commission on Radiological protection. ICRP Publication 103, 2019, Ann ICRP 37 (2-4).
[4] Kalender, Dose In X-Ray Computed Tomography, Phy Med Biol, 2014, 59 hal RI 29-RI 50.
[5] E. Manzil, Faktor Phantom dan Estimasi Dosis Efektif dari Hasil Pengukuran Computer Tomography Dose Index (CTDI), Skripsi, Program Studi Fisika, Peminatan Fisika Medis dan Biofisika, Fakultas Matematika dan Ilmu Pengetahuan Alam, Universitas Indonesia, 2011.
[6] Hiswara Eri, Proteksi Radiasi Lensa Mata, Prosiding Seminar Nasional Sains dan Teknologi Nuklir PTNBR – BATAN Badung 04 Juli 2013.
[7] ICRP, Statement on Tissue Reactions, ICRP ref 4825-3093-1464, 2011.
[8] Latifah Risatul, Penetapan Local Diagnostic Reference (LDRL) Pasien Padiatrik Pada Pemeriksaan CT Kepala Berdasarkan Nilai SSDE. Ejournal Undip. Program Studi Fisika Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Air langga Surabaya, 2019.
[9] America Associatio of Psicists in Medicine, Bascic Quality Control in Diagnostic Radiolog, AAPM Report No.4, New York, 1977.
[10] Rusmanto dkk, Pedoman Teknis Penyusunan Tingkat Panduan Paparan Medik atau Diagnostic Reference Level (DRL) Nasional, Pusat Pengkajian Sistem dan Teknologi Pengawasan Fasilitas Radiasi dan Zat Radioaktif Badan Pengawas Tenaga Nuklir, 2011
[11] Anam Choirul dkk, A fully automated calculation of size-specific dose estimates (SSDE) in thoracic and head CT examinations, Journal of Physics Conference Series, Vol 694, Conference 1, 2016.
[12] A. Fuziyah, Pengaruh Variasi Rotation Time Terhadap Nilai DLP (Dose Length Product) Dan Image Noise Pada Pesawat MSCT 128 Slice, Skripsi, Fakultas Vokasi Universitas Airlangga, 2016.
Published
2024-02-28
How to Cite
PALUPI, Shinta et al. Determination of Patient Dose on Head Computed Tomography Scan on Risk Factors of Cataract Using Size-Specific Dose Estimate (SSDE). BULETIN FISIKA, [S.l.], v. 25, n. 1, p. 37 – 42, feb. 2024. ISSN 2580-9733. Available at: <https://ojs.unud.ac.id/index.php/buletinfisika/article/view/81423>. Date accessed: 21 nov. 2024. doi: https://doi.org/10.24843/BF.2024.V25.i01.p05.