Diagnostic Reference Levels (DRLs) for SPECT Examinations at the Nuclear Medicine Installation of the RSUD A.W. Sjahranie Samarinda

Abstract

Diagnostic reference Level (DRL) is an investigational tool used to help optimize patient protection during diagnostic and interventional procedures in nuclear medicine, the administered activity is based on the patient's body weight. This study aims to determine the diagnostic reference levels (DRLs) for SPECT Examinations: Bone Scan using radiopharmaceutical 99mTc MDP, Whole Body Scan using radiopharmaceutical 99mTc MIBI, and Thyroid Whole-Body Scan using radiopharmaceutical 131I. This study included patient aged 15 to 60 years with body weight ranging 35 to100 kg. The DRL was calculated based on the 75th percentile and the results were compared with the BAPETEN DRL and previous research. Finding. The DRLs determined for RSUD AWS Samarinda were 999MBq for Bone Scan examination using 99mTc MDP, 921.3 MBq for Whole Body Scan using 99mTc MIBI and 3145 MBq for Thyroid Whole-Body Scan. Based on results, the DRL of Bone Scan and Thyroid WBS exceed the BAPETEN DRL while the DRL for Whole Body Scan using 99TC-MIBI is below the BAPETEN DRL.

Downloads

Download data is not yet available.

References

[1] De Souza Ribeiro, J. C., de Mendes, J. D. S. & de Sá, L. V. Attributable patient risk in nuclear medicine procedures and establishment of diagnostic reference levels. J. Appl. Clin. Med. Phys. 24, 1–9 (2023).
[2] Lorberboym, M. Fundamentals of single-photon emission computed tomography (SPECT) and SPECT/CT imaging. 41–56 (2019).
[3] Mattsson, S. & Christoph, H. Radiation Protection in Nuclear Medicine. (Springer Berlin Heidelberg, 2013). Doi:10.1007/978-3-642-31167-3.
[4] Goldenhart, A. L. & Senthilkumaran, S. Nuclear Medicine Test. (statpearls Publishing, 2022).
[5] Ziessman, H., O’Malley, J. & Thrall, J. Nuclear Medicine: The Requisites. (Elsevier, 2014).
[6] Y. Du and H. Zaidi. Single-Photon Emission Computed Tomography: Principles and Applications. Encyclopedia of Biomedical Engineering. 3, 493–506 (2019). Doi:10.1016/B978-0-12-801238-3.10891-8.
[7] Murshed, H. Radiation Physics, Dosimetry, and Treatment Planning. Fundamentals of Radiation Oncology (2019). Doi:10.1016/b978-0-12-814128-1.00001-51.00001-5.
[8] Crișan, G. Et al. Radiopharmaceuticals for PET and SPECT Imaging: A Literature Review over the Last Decade. Int. J. Mol. Sci. 23, (2022)
[9] Kane, S. M. & Davis, D. D. Technetium-99m. (statpearls Publishing, 2022).
[10] Mondrida, G., Widjaksana, W., Kurniasih, D., Lestari, E. & Ariyanto, A. Pemastian Kemampuan KIT Radiofarmaka PTRR – BATAN untuk Ditandai dengan 99m-Tc Aktivitas Tinggi. Pros. Semin. Nas. Inov. Dan Pendayagunaan Teknol. Nukl. 83–90 (2020).
[11] Alsharef, S., Alanazi, M., Alharthi, F., Qandil, D. & Qushawy, M. Review about radiopharmaceuticals: Preparation, radioactivity, and applications. Int. J. Appl. Pharm. 12, 8–15 (2020).
[12] Lee, U. J., Kim, M. J. & Kim, H. R. Radioactive iodine analysis in environmental samples around nuclear facilities and sewage treatment plants. Nucl. Eng. Technol. 50, 1355–1363 (2018).
[13] Angelo, J. A. Nuclear Technology. Industrial and Engineering Chemistry. 52, (Greenwood Press, 2004).
[14] Abe, K. Et al. The 2020 national diagnostic reference levels for nuclear medicine in Japan. Ann. Nucl. Med. 34, 799–806 (2020).
[15] Alnaaimi, M. A. Et al. National Diagnostic Reference Levels for Nuclear Medicine in Kuwait. J. Nucl. Med. Technol. 50, 54–59 (2022).
[16] Song, H. C. Et al. Diagnostic Reference Levels for Adult Nuclear Medicine Imaging Established from the National Survey in Korea. Nucl. Med. Mol. Imaging (2010). 53, 64–70 (2019).
[17] Taty, A. L., Mbo, G. E. & Traore, S. Local Drl In Nuclear Medicine Department Of Cancerology Institute Of Libreville. 11, 60–63 (2023).
[18] Fayad, H. Et al. National diagnostic reference levels for nuclear medicine in Qatar. J. Nucl. Med. Technol. 00974, jnmt.122.264415 (2022).
[19] Thorat, D. H. P. New Course in Statistic. (Ashok Yakkaldevi, 2022).
[20] Vañó, E. Et al. ICRP Publication 135: Diagnostic Reference Levels in Medical Imaging. Ann. ICRP 46, 1–144 (2017).
[21] BAPETEN. Keputusan Kepala Badan No 3426/K/XI/2022 Tahun 2022 Tentang Penetapan Nilai Tingkat Panduan Diagnostik Indonesia atau I-DRL untuk Pemeriksaan Pasien dengan Kedokteran Nuklir Diagnostik dan Pesawat Sinar-X Fluoroskopi Intervensional. In (2022).
[22] Narawong, T. Et al. The survey of local diagnostic reference levels ( drls ) for administered activity in diagnostic nuclear medicine at Rajavithi Hospital. 46, 1–7 (2021).
Published
2025-02-17
How to Cite
RUDYANTI, Nadia; MUNIR, Rahmawati; PUTRI, Erlinda Ratnasari. Diagnostic Reference Levels (DRLs) for SPECT Examinations at the Nuclear Medicine Installation of the RSUD A.W. Sjahranie Samarinda. BULETIN FISIKA, [S.l.], v. 26, n. 1, p. 39 – 45, feb. 2025. ISSN 2580-9733. Available at: <https://ojs.unud.ac.id/index.php/buletinfisika/article/view/121491>. Date accessed: 22 feb. 2025.