Pemanfaatan Autotransformator Sebagai Pengontrol Arus Start Motor Induksi Tipe LH 73204 Guna Menjaga Kesetabilan Tegangan Listrik di Laboratorium Konversi Energi Teknik Elektro Universitas Udayana
Abstract
Practicum activities at the Energy Conversion Laboratory of Electrical Engineering Udayana University, using induction motors that operated directly connected to the power source, so that start current of the motor becomes large enough to cause electrical voltage stability to be disturbe. Conditions like these can damage other laboratory equipment. So that research using autotrasformator as a starting, the aims to produce a model of controlling the starting current on the operation of induction motor Type LH73204. In research, the input voltage to the motor is gradually lowered from 220 Volts to 88 Volts with autotransformator at the start of the motor, then motor starting current is observed for each phase of the input voltage drop. Data were tabulated and analyzed descriptively, showed that the utilization autotransformator starting current operation induction motor type LH 73204 capable suppressed 44,11% or 3 Apere lower. so that becomes a model and test method for controlling the starting current induction motor. This model is very useful for maintaining electrical voltage stability, so that laboratory equipment works optimally.
Downloads
References
[2] Sultan, A.B. Muljono, and I.M.A. Nrartha, Visualisasi Pengasutan Motor Induksitiga Fasa Berbasis Programmable Logic Control, Dielektrika, [P-ISSN 2086-9487] [E-ISSN 2579-650X] Vol.4, No.1: 58-69, 2017.
[3] A. Widyatmoko, I.B.F. Citarsa, and I.N.W. Satiawan, Realisasi Teknik Pengereman Dinamik.(Dynamic Braking) Untuk Motor Induksi Tiga Fase Menggunakan Arduino Uno, Dielektrika, [P-ISSN 2086-9487] [E-ISSN 2579-650X] Vol.4, No.1: 31-38, 2017.
[4] A.H. Santoso, R.N. Hasanah, and H. Suyono, Pengaruh Tipe Belitan Terhadap Unjuk Kerja Motor Induksi satu fasa, EECCIS Vol. 12, No. 2, 2018.
[5] Z. Anthony, E. Erhaneli, Desain Lilitan Motor Induksi 1 Fasa dengan 4 Kumparan yang Tidak Identik Sama (Studi Kasus: Daya Keluaran dan Efisiensi Motor), EECCIS Vol. 12, No. 2, 2018.
[6] M. Putra, Z. Bahri, and M.F. Siregar, Penggunaan Transformator Arus Untuk Pencegahan Pemakaian Arus Ilegal, JESCE, p-ISSN: 2549-628X e-ISSN: 2549-6298, 2018.
[7] A.A.N. Amrita, W.G. Ariastina, and I.B.G. Manuaba, Study of Transformer Lifetime Due to Loading Process on 20 KV Distribution Line, JEET, p-ISSN: 2549-8304 e-ISSN: 2622-0393, 2018.
[8] K.W. Widiatmika, I.W.A.Wijaya, and I.N. Setiawan, Analisis Penambahan Transformator Sisipan Untuk Mengatasi Overload Pada Transformator DB0244 di penyulang sebelanga, Spektrum, Volt. 5 No. 2, 2018.
[9] M.D. Noviantari, I.N. Suweden, and I.M. Mataram, Analisis Stabilitas Sistem Tenaga Listrik Dengan Automatic Generation Control (AGC) Dua Area Menggunakan Metode Fuzzy Logic Controller, MITE, p-ISSN: 1693-2951; e-ISSN: 2503-2372, Vol. 17, No. 2, 2018.
[10] I.G.A.T.K. Putra, I.W. Rinas, and Y.P. Sudarmojo, Analisis Pengaruh Pemasangan Dynamic Voltage Restorer (DVR) Terhadap Kedip Tegangan Akibat Gangguan Hubung Singkat 3 Fasa Pada Penyulang Kampus, MITE, p-ISSN: 1693-2951; e-ISSN: 2503-2372, Vol. 16, No. 03, 2017. .
This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
This work is licensed under a Creative Commons Attribution 4.0 International License