Analisis Stabilitas Sistem Tenaga Listrik Dengan Automatic Generation Control (AGC) Dua Area Menggunakan Fuzzy Logic Controller

  • Made Dwi Noviantara Universitas Udayana
  • I Nengah Suweden
  • I Made Mataram

Abstract

The power system must be able to server the load in a sustainable manner with good service quality, such as constant voltage and frequency, quickly stabilized when load changes occur. The control generator automatically changes the frequency to the highest value when the system changes every time. This is called AGC. To keep the frequency in a stable state required frequency control system. Currently developing a lot of control system with fuzzy logic method. The simulation is performed using 5 membership functions and gives a loading of 0.1 pu, using MATLAB-Simulink software. From the analysis result, the comparison of output of frequency response in overshoot condition with conventional method yielded , settling time of 20.5 second. While the fuzzy logic controller method produces frequency response output in the overshoot state that is , settling time is 12 seconds. Whit the fuzzy logic controller method produces better performance and faster than conventional methods.

Downloads

Download data is not yet available.

References

[1] Robandi, Imam. Desain System Tenaga Modern. Yogyakarta: ANDI Yogyakarta. 2006.
[2] NN. Aturan Jaringan Sistem Tenaga Listrik Jawa-Madura-Bali. Departemen Energi dan Sumber Daya Mineral. 2007.
[3] Aryanata Gusti Made Ngurah Christy. “Studi Analisis governor sebagai Load Frequency Control pada PLTG menggunakan Fuzzy Logic Controller”. (Skripsi). Denpasar : Universitas Udayana. 2017.
[4] I M A Nrartha, A B Muljono. Pengaruh Power System Stabilizer Pada Sistem Tenaga Listrik Dengan Unit Pembangkit Tersebar. Majalah Ilmiah Teknologi Elektro. Vol.9, No.1. 2010.
[5] Mataram I Made. Perbandingan Penggunaan Jumlah dan Jenis Fungsi Keanggotaan Pada Metode Logika Fuzzy Untuk Pengontrolan Frekuensi Beban. Badung: Universitas Udayana. 2013.
[6] Rishabh Verma, Shalini Pal, Sathans. Fuzzy Gain Scheduled Automatic Generation Control of Two Area Multi Unit Power System. Stdt, Dept of Engineering National Institute of Thecnology. Akurukshetra: India. 2013.
[7] Kundur, P. Power System Stability and Control. Toronto:Mcgraw-Hill. 1994.
[8] Saadat, Hadi. Power System Analysis.Tata McGraw-Hill Edition. New Delhi. 2002.
[9] Y.V.L Charitha Reddy, Dr. M.S. Krishnarayalu. Automatic Generation Control of Multi-area Power System using Active Disturbance Rejection Control. International Journal of Enggineering Trens and Technology (IJETT). Vol.43 No.4. (ISSN:2231-5381). 2017.
[10] Mataram I Made. Unjuk Kerja Fuzzy Logic Static Synchrounous Compensator (FLSTATCOM) Untuk Meningkatkan Tegangan Sistem. Majalah Ilmiah Teknologi Elektro. Vol.15, No.1. (ISSN: 1963-2951). 2016.
Published
2018-09-28
How to Cite
NOVIANTARA, Made Dwi; SUWEDEN, I Nengah; MATARAM, I Made. Analisis Stabilitas Sistem Tenaga Listrik Dengan Automatic Generation Control (AGC) Dua Area Menggunakan Fuzzy Logic Controller. Majalah Ilmiah Teknologi Elektro, [S.l.], v. 17, n. 2, p. 263-270, sep. 2018. ISSN 2503-2372. Available at: <https://ojs.unud.ac.id/index.php/mite/article/view/37360>. Date accessed: 19 nov. 2024. doi: https://doi.org/10.24843/MITE.2018.v17i02.P15.