Analysis of Rewetting Time and Temperature Distributions During Cooling Process in Vertical Rectangular Narrow
Abstract
AbstractCooling process to analyze effect of gap size to rewetting time and temperature distributions
were studied from transient temperature of surface plate. It as result of experiment using two
vertical plate with the initial temperature about 600°C. Debit and temperature of cooling water
are 0,09 L/s and saturated temperature. The gap sizes were changed from 1 mm, 2 mm, and 3
mm. As the results showed that the smaller the gap size, the longer the rewetting time. Pattern
of temperature distribution is similar at initial condition for all of gap sizes and the smaller the
gap sizes, the longer the time of decreasing temperature.
Keywords: Cooling process, rewetting time, temperature distribution.
Abstrak
Proses pendinginan untuk menganalisa pengaruh ukuran celah terhadap waktu pembasahan
dan distribusi temperatur diamati dari transient temperatur permukaan plat. Penelitian
dilakukan menggunakan dua plat vertikal dengan temperatur awal 6000C. Debit dan temperatur
air pendingin adalah 0,09 L/s dan temperatur jenuh. Ukuran celah divariasikan dari 1 mm, 2
mm dan 3 mm. Hasil penelitian menunjukkan bahwa semakin kecil ukuran celah semakin
panjang waktu rewetting. Pola distribusi temperaursama pada kondisi awal untuk semua
ukuran celah, semakin kecil ukuran celah semakin panjang waktu untuk penurunan
temperatur.
Kata kunci: Proses pendinginan, rewetting time, distribusi temperatur
Downloads
Keywords
This work is licensed under a Creative Commons Attribution 4.0 International License.