Gangguan Penyulang Akibat Kegagalan Proteksi di Circuit Breaker Output Pelanggan Pada Gardu Distribusi MP 244

  • Muhammad Rifqi Setyanto Universitas Singaperbangsa Karawang
  • Yuliarman Saragih Universitas Singaperbangsa Karawang

Abstract

The distribution network requires a protection system so that the electric power is distributed optimally using CBO cubicles (Output Circuit Breakers). the differencese with general cubicles are additional devices in the form of Circuit Breakers or PMT, Current Transformers (CT), Potential Transformers (PT), and relays. CBO installation is important to minimize disturbance to the feeder. Medium Voltage Network has spindle, mesh, and radial configuration. The MP 244 substation is also equipped with Ground Fault Detection (GFD) which functions as a short circuit fault detector to the ground and to speed up localizing interference on 20 kV. Maintenance of medium voltage distribution networks is divided into replacement, predictive, preventive, and corrective maintenance. Meanwhile, in the maintenance of the 20kV cubicle, PLN officers must also follow various stages regulated in certain SOPs. The aim of the research is to maintain the 20 kV cubicle in the medium voltage distribution network based on the applicable SOP so that protection failures at the MP 244 distribution substation do not recur.


Keyword— Circuit Breaker Output (CBO); Ground Fault Detector (GFD); Network; Corona; Cubicles 20kV; Medium Voltage

Downloads

Download data is not yet available.

References

[1] H. W. Wahyu Adi Prasetiyo, “SIMULATOR KUBIKEL MINIMUM UNTUK INVESTIGASI DISTRIBUSI TENAGA LISTRIK 20 KV,” GEMA TEKNOLOGI, vol. 17, no. 4, hlm. 164–169, 2014.
[2] H. S. R. G. Nina Lestari, “SISTEM PEMANTAUAN KUBIKEL TEGANGAN MENENGAH BERBASIS INTERNET OF THINGS,” JURNAL INFOTRONIK, vol. 5, no. 1, hlm. 37–42, Jun 2020.
[3] Ashar Arifin, “Pengertian, Fungsi Dan Komponen Kubikel Tegangan Menengah,” CARA ILMU, Nov 13, 2020.
[4] P. A. Y. Hendra Mars Setiawan, “METODE PENGOPERASIAN KUBIKEL 24 KV TIPE SM6 PADA LABORATORIUM PROTEKSI DAN DISTRIBUSI DI POLITEKNIK NEGERI BANJARMASIN,” Integrated Lab Journal, vol. 7, no. 2, hlm. 68–79, Okt 2019.
[5] Y. S. I. U. L. Rizal Pratama, “Rancang Bangun Alat Monitoring Arus dan Tegangan Berbasis Mikrokontroler pada Studi Kasus Prototype Gardu Distribusi PLN,” Rekayasa Elektrikal dan Energi, vol. 5, no. 2, hlm. 88–92, Jan 2023.
[6] I. R. C. S. F. A. S. Faisal Irsan Pasaribu, “Analisa Proteksi Over Current Relay Pada Jaringan Tegangan Menengah 20KV Di PELINDO 1 Cabang Belawan,” Rekayasa Elektrikal dan Energi, vol. 4, no. 1, hlm. 18–26, Jul 2021.
[7] M Refhan Naparin, “ANALISIS KOORDINASI PROTEKSI OVERCURRENT RELAY PADA JARINGAN DISTRIBUSI 70 kV PT MAKMUR SEJAHTERA WISESA,” Yogyakarta, Des 2018.
[8] L. S. P. H. T. Rudolfus Masarrang, “Efek Korona pada Saluran Transmisi Gardu Induk Tello Sulawesi Selatan,” Jurnal Teknik Elektro dan Komputer, vol. 8, no. 2, hlm. 67–74, Mei 2019.
[9] Rusdi Syahbanda, “ANALISA TERBENTUKNYA KORONA PADA SALURAN KUBICLE TEGANGAN 20 KV SERTA PENGARUHNYA TERHADAP RUGI-RUGI DAYA,” LENSA, vol. 2, no. 48, hlm. 14–21, Sep 2019.
[10] A. M. M. O. A. Nurmiati Pasra, “Analisa Efek Korona Pada Sistem Distribusi Tenaga Listrik 20 kV Pada Gardu Beton,” JURNAL ILMIAH SUTET, vol. 8, no. 2, hlm. 103–113, Jul 2018.
[11] DON BOSCO, “ANALISIS DAN SIMULASI TEGANGAN AWAL TERBENTUKNYA KORONA PADA MODEL KUBIKEL,” Depok, Jan 2008.
[12] R. F. A. A. V. H. A. Anggara Trisna Nugraha, “Design and Fabrication of Temperature and Humidity Stabilizer on Low Voltage Distribution Panel with PLC-Based Fuzzy Method to Prevent Excessive Temperature and Humidity on The Panel,” jeeemi, vol. 4, no. 3, hlm. 170–177, Jul 2022.
[13] N. W. R. F. R. R. F. A. A. T. N. Sindy Yurisma Sheila, “Desain and Build a Medium Voltage CubiclesTemperature and Humidity Optimization Tool to Minimize the Occurrence of Corona Disease with the PLC-Based Fuzzy Method,” ijeeemi, vol. 4, no. 4, hlm. 192–198, Nov 2022.
[14] D. N. B. S. Diva Adin Maulana, “ANALISA SUSUT DAYA DAN DROP TEGANGAN TERHADAP JARINGAN TEGANGAN MENENGAH 20KV PADA GARDU INDUK PANDEAN LAMPER SEMARANG,” dalam KONFERENSI ILMIAH SISWA UNISSULA (KIMU) 2, Okt 2019, hlm. 382–389.
[15] Ashar Arifin, “Materi Lengkap Jaringan Distribusi Tenaga Listrik,” Mei 27, 2020.
[16] Tri Watingsih, “SISTEM JARINGAN DISTRIBUSI TEGANGAN MENENGAH,” Teodolita, vol. 13, no. 2, hlm. 75–84, Des 2012.
[17] A. B. Badaruddin, “STUDI ANALISA PENGEMBANGAN DAN PEMANFAATAN GROUND FAULT DETECTOR (GFD) PADA JARINGAN 20 KV PLN DISJAYA TANGERANG,” Jurnal Teknologi Elektro, vol. 4, no. 1, hlm. 1–5, Jan 2013.
[18] Aditya Ronisutra, “PEMELIHARAAN GARDU DISTRIBUSI AREA BULUNGAN UNTUK MENGURANGI GANGGUAN SISTEM JARINGAN 20 KV DI PLN UP3 BULUNGAN,” Jakarta, Jul 2022.
[19] Hendra Anwar Siahaan, “ANALISIS SUSUT ENERGI UNTUK TINDAKAN PEMELIHARAAN JARINGAN TEGANGAN MENENGAH DI PT PLN (PERSERO) ULP SIBORONGBORONG,” Okt 2022.
[20] “PEMELIHARAAN JARINGAN TEGANGAN RENDAH DAN TEGANGAN MENENGAH,” Bengkalis, Agu 2022.
[21] Hardine, Linkha, Dian Budhi Santoso, and Ridwan Satrio Hadikusuma. "Analysis of The Influence of Star Delta System in Reduce Electric Starting Surge in 3 Phase Motors." Electrician 16.2 (2022): 208-214.
Published
2023-06-05
How to Cite
SETYANTO, Muhammad Rifqi; SARAGIH, Yuliarman. Gangguan Penyulang Akibat Kegagalan Proteksi di Circuit Breaker Output Pelanggan Pada Gardu Distribusi MP 244. Majalah Ilmiah Teknologi Elektro, [S.l.], v. 22, n. 1, p. 111-116, june 2023. ISSN 2503-2372. Available at: <https://ojs.unud.ac.id/index.php/jte/article/view/96781>. Date accessed: 05 may 2024. doi: https://doi.org/10.24843/MITE.2023.v22i01.P14.