SAIFI untuk Evaluasi Keandalan Sistem Distribusi Tenaga Listrik pada Jaringan Transmisi Menengah 20 KV

  • Annisa Larasati Febrianingrum Universitas Sebelas Maret
  • Subuh Pramono Universitas Sebelas Maret

Abstract

The Medium Voltage Network is an electrical power system between main substations and distribution substations with the scope from the out-going terminal of the power breaker to the in-coming separation / protection equipment for 20kV distribution transformer. The Medium Voltage Network distributes electricity and deals with customers must pay attention for the level of reliability which is able to supply electric power to consumers on a continuous basis. The reliability level of the distribution system can be determined by calculating SAIFI (System Average Interruption Frequency Index), which is the reliability index of the number of blackout frequencies. Based on the results of the calculation and analysis of the system-based reliability index that the obtained results of 10.89 times/customer/year with total energy not served was 57772 kWh which were considered unreliable distribution system according to the SPLN 68-2: 1986 index standard. Furthermore, it is necessary to analyze, evaluate the causes of trips and budget policies as an effort to reduce the value of SAIFI. Preventive activities include: routine inspections, installation of wire insulation, as well as utilizing IoT technology, databases and GPS for system digitization for distribution system reliability.


Keyword: Medium voltage network, feeder, trip, reliability, SAIFI.

Downloads

Download data is not yet available.

References

[1] D. Dasman, H. Handayani, “Evaluasi Keandalan Sistem Distribusi 20 kV Menggunakan Metode SAIDI dan SAIFI di PT. PLN (Persero) Rayon Lubuk Alung Tahun 2015,” Jurnal Teknik Elektro, vol. 6, no. 2, pp.170-179, 2017.
[2] R. S. Hartati, Penentuan Angka Keluar Peralatan Untuk Evaluasi Keandalan Sistem Distribusi Tenaga Listrik. Universitas Udayana, Denpasar, 2007.
[3] Marsudi, Djiteng, Operasi Sistem Tenaga Listrik. Yogyakarta: Graha Ilmu, 2006.
[4] A. S. Pabla, Electric Power Distribution Systems, McGraw-Hill, New Delhi, 1981.
[5] F. Praditama, T. Utomo, M. Shidiq, “Analisis Keandalan Dan Nilai Ekonomis di Penyulang Pujon PT. PLN (PERSERO) Area Malang,” Jurnal Mahasiswa TEUB, vol. 2, no. 4, 2014.
[6] Kelompok Kerja Standar Kontruksi Jaringan Disribusi Tenaga Listrik dan Pusat Penelitian Sains dan Teknologi Universitas Indonesia, Kriteria Disain Enjinering Konstruksi Jaringan Distribusi Tenaga Listrik. PT. PLN (Persero), Jakarta Selatan, 2010
[7] C.H. Saputro, Keandalan Sistem Distribusi Jaringan SUTM Akibat Gangguan Pohon di PT. PLN (Persero) UP3 Semarang, Universitas negeri Semarang.,2019.
[8] A.A. Rahim, Analisis Keandalan Sistem Distirbusi Pada Sistem Jaringan Tegangan Menengah 20 KV Gardu Induk Maros, Universitas Negeri Makasar, 2020.
[9] S.S. Wibowo, Analisa Sistem Tenaga: Analisa Sistem Tenaga, vol. 1, UPT Percetakan dan Penerbitan Polinema, 2018.
Published
2022-07-08
How to Cite
FEBRIANINGRUM, Annisa Larasati; PRAMONO, Subuh. SAIFI untuk Evaluasi Keandalan Sistem Distribusi Tenaga Listrik pada Jaringan Transmisi Menengah 20 KV. Majalah Ilmiah Teknologi Elektro, [S.l.], v. 21, n. 1, p. 1 - 6, july 2022. ISSN 2503-2372. Available at: <https://ojs.unud.ac.id/index.php/jte/article/view/75013>. Date accessed: 28 mar. 2024. doi: https://doi.org/10.24843/MITE.2022.v21i01.P01.